Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Japanese Journal of Drug Informatics ; : 152-158, 2020.
Article in Japanese | WPRIM | ID: wpr-811007

ABSTRACT

Introduction: Voriconazole (VRCZ) is a triazole antifungal agent for which therapeutic drug monitoring (TDM) is recommended. At Juntendo University Hospital, the VRCZ TDM implementation rate was 42% between January 2011 and October 2017. Here, we report that modifications to the hospital’s drug ordering system improved the implementation rate of VRCZ TDM.Method: In August 2018, the drug ordering system was modified so that a message appeared on the screen to notify clinicians of the need to monitor VRCZ blood concentrations and to recommend a date for sample collection. In addition, the laboratory orders for VRCZ levels were digitized. We compared two one-year periods before and after implementation of the modifications (August 2017 to July 2018 and August 2018 to July 2019) to verify the effect of the changes.Result: Results showed an increase in the TDM implementation rate: 12 patients (42.8%) received TDM before modification of the system, and 26 patients (92.9%) received TDM after modification of the system. Further, the rate of blood sampling at the recommended time point for estimating blood concentration (day 5-7 after the start of administration) improved after system modification, i.e., blood samples were collected from 18 patients (64.3%) at the steady state point. In contrast, blood samples were collected from only 6 patients (21.4%) before system modification. When blood concentrations deviated from the target range in patients who received TDM, clinicians took appropriate actions, such as reducing drug doses, prescribing drug holidays, or discontinuing medications.Conclusion: A system that provides information related to VRCZ blood concentration measurements can help clinicians provide patients with optimal pharmacotherapy.

2.
Intestinal Research ; : 265-272, 2019.
Article in English | WPRIM | ID: wpr-764132

ABSTRACT

BACKGROUND/AIMS: There are few prospective studies on cold forceps polypectomy (CFP) using jumbo cup forceps. Therefore, we examined patients with diminutive polyps (5 mm or smaller) treated with CFP using jumbo cup forceps to achieve an adenoma-free colon and also assessed the safety of the procedure and the recurrence rate of missed or residual polyp after CFP by performing follow-up colonoscopy 1 year later. METHODS: We included patients with up to 5 adenomas removed at initial colonoscopy and analyzed data from a total of 361 patients with 573 adenomas. One-year follow-up colonoscopy was performed in 165 patients, at which 251 lesions were confirmed. RESULTS: The one-bite resection rate with CFP was highest for lesions 3 mm or smaller and decreased significantly with increasing lesion size. Post-procedural hemorrhage was observed in 1 of 573 lesions (0.17%). No perforation was noted. The definite recurrence rate was 0.8% (2/251 lesions). The probable recurrence rate, which was defined as recurrence in the same colorectal segment, was 17%. Adenoma-free colon was achieved in 55% of patients at initial resection. Multivariate analysis revealed that achievement of an adenoma-free colon was significantly associated with number of adenomas and years of endoscopic experience. CONCLUSIONS: CFP using jumbo biopsy forceps was safe and showed a high one-bite resection rate for diminutive lesions of 3 mm or smaller. The low definite recurrence rate confirms the reliability of CFP using jumbo biopsy forceps. Number of adenomas and years of endoscopic experience were key factors in achieving an adenoma-free colon.


Subject(s)
Humans , Adenoma , Biopsy , Colon , Colonoscopy , Follow-Up Studies , Hemorrhage , Multivariate Analysis , Polyps , Prospective Studies , Recurrence , Surgical Instruments
3.
Japanese Journal of Cardiovascular Surgery ; : 93-100, 1989.
Article in Japanese | WPRIM | ID: wpr-364784

ABSTRACT

In order to reduce the blood transfusion volume in open heart surgery, the new blood autotransfusion technique using cardiotomy reservoir unit BCR 3538, which was configured to serve also as a receptacle for postoperative mediastrinal drainage, was introduced. To investigate the utility and the problem in this system, every clotting factor, platelets' function and the extent of the hemolysis were measured serially both in patients' arterial blood and the shed mediastinal blood. The bank blood transfusion was significantly reduced to 250ml±330ml by this system compared to the 1080ml±820ml in the cases of usual system (<i>p</i><0.01). Every clotting factor recovered well in patients' arterial blood after cardiopulmonary bypass (CPB). In the reservoir blood, the clotting factor IX, XI, XII were extremely suppressed at 1h CPB, and 3h after the CPB, every clotting factor except fibrinogen (42±28mg/dl) showed the quite higher activity, such as factor VIII 400%, IX 365%, XI 72%, XII 267%. Namely, the anticoagulability of the reservoir blood was maintained due to the effect of the residual heparin at 1h after the CPB, and due to the contact defibrinogation of the shed mediastinal blood at 3h after CPB. The free hemoglobin level was extremely high on the reservoir blood at 3h after CPB. In 6 cases, the autologous blood retransfusion was abandoned by clott formation in the unit because of the contamination of the intraoperatively used fibrin glue. From this study, the autologous blood transfusion using cardiotomy reservoir BCR 3538 was useful not only for saving the transfusion of the bank blood but also the hemostasis after CPB. But to reduce the hemolysis in this system, and to establish the safety against the other clotting material such as fibrin glue were the problems which should be resolved in future. I appreciate the kind support of Alexander von Humboldt Foundation for this study.

4.
Japanese Journal of Cardiovascular Surgery ; : 129-133, 1989.
Article in Japanese | WPRIM | ID: wpr-364703

ABSTRACT

The surface-coated vascular stent of shape memory alloy was made for use of occlusion of pseudo-lumen of the dissecting aneurysm of the aorta, as the usage of shape memory alloy in angioplasty, and the metal flexible delivery catheter was also made for the introduction of the stent. In the present study, antithrombogenicity of the vascular stent was much improved by surface-coating with EPTFE and segmented polyurethane. The long-term usage of the stent was confirmed by radiological, macroscopic, and electron microscopic examinations. Moreover, the metal flexible delivery catheter was demonstrated to be of much benefit for the introduction of the surface-coated vascular stent of shape memory alloy.

SELECTION OF CITATIONS
SEARCH DETAIL